How do I read my YORK HVAC model number?
- 1st digits X is the plant. X was made in Mexican.
- 2nd digits B are the month. B is in February.
- 3rd digits F are the year.
- 4th digits M are the TYPES OF ITEM.
- The last 6 numbers.
- 1st digits W are Manufacturing Plant.
- 2nd and 4th digits 0 and 4 (number) is the year of manufacture.
- 3rd digits E are the month.
How many sq ft can a 5 ton AC cool?
Air Conditioning Square Footage Range by Climate Zone
| ZONE 1 | ZONE 3 | |
|---|---|---|
| 3 Tons | 1501 – 1800 sf | 1601 – 1900 sf |
| 3.5 Tons | 1801 – 2100 sf | 1901 – 2200 sf |
| 4 Tons | 2101 – 2400 sf | 2201 – 2600 sf |
| 5 Tons | 2401 – 3000 sf | 2601 – 3200 sf |
How many tons is a York air conditioner?
Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 – 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 2 tons. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the “RLA” rating on the data plate.
How to calculate York tonnage by model number?
Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit. Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit.
What are the model numbers for a York Furnace?
For York, you should look for first two numbers in the model number. They are divisible by 6 or 12, which represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.
What’s the difference between carrier 48tc16 and York zx04?
However, they usually don’t include the precise tonnage. My thought; because of the 2.5, 7.5 and 12.5 ton units which if expressed with whole numbers would cause confusion. Most all manufacturers when referencing tonnage round up. Carrier: 48TC16 is actual their 15 ton unit. York: ZX04 – is a 3 ton unit.
Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit. Take the 4th,5th & 6th digits in the m/n and divide by 12 (12,000 btu/ton). For example: D2CG180N24046ECB would be a 15 ton unit.
Here’s a rundown of the range you will encounter: 18 = 1.5 tons, 24 = 2 tons, 30 – 2.5 tons, 36 = 3 tons, 42 = 3.5 tons, 48 = 4 tons, and 60 = 5 tons. And this is another one that is 2 tons. If you are unsure whether you have found the right two numbers, you can double-check it by looking for the “RLA” rating on the data plate.
For York, you should look for first two numbers in the model number. They are divisible by 6 or 12, which represent the nominal BTU of the system in thousands. A ton of air conditioning equals 12,000 BTU, and 48 divided by 12 equals 4, so the data plate below indicates the system is 4 tons.
However, they usually don’t include the precise tonnage. My thought; because of the 2.5, 7.5 and 12.5 ton units which if expressed with whole numbers would cause confusion. Most all manufacturers when referencing tonnage round up. Carrier: 48TC16 is actual their 15 ton unit. York: ZX04 – is a 3 ton unit.